Jake Morrison, Licensed General Contractor · Last reviewed November 4, 2026

Furnace Size Calculator

Get the heating load in BTU from your square footage, or measure it from last year's gas, propane or oil bills. Then see which standard furnace sizes fit it, and whether the one in your basement ever did.

Furnace size calculator: estimate your home's design heating load from square footage or from last year's fuel bills, then see which standard furnace sizes fit it.

sq ft

Count every heated floor. Leave out the garage and an unheated basement.

Insulation and air sealing

Average: typical insulated home

ft

Your current furnace (optional)

Btu/h
Btu/h

Both are on the rating plate inside the burner door. The tool checks the furnace you have against the load.

The new furnace

Enter the heated square footage. You'll get the heating load, the furnace size that fits it, and how every standard size compares.

Estimates only. Verify against local building code and manufacturer specs before you buy. A furnace replacement should be sized from an ACCA Manual J load calculation, and many jurisdictions require one for the permit. Use this to check the number a contractor gives you, not to replace it. Gas appliances need carbon monoxide alarms on every sleeping floor.

How to use this furnace size calculator

  1. Pick your city. It sets the climate zone, the winter design temperature and the heating degree days for 71 US cities. If yours isn't listed, pick the nearest one or enter your own numbers.
  2. Choose a method. "By square footage" is the quick rule of thumb. "From my fuel bills" takes last year's gas, propane or oil use and works out what your house actually loses. Use the bills if you have them.
  3. Describe the new furnace. Gas or propane at the efficiency (AFUE) you are pricing, or electric at your supply voltage.
  4. Add your current furnace if you like. The input and output figures are on the rating plate. The tool tells you how it compares with the load.
  5. Read the ladder. Every standard size is shown against your load. The one marked "Pick" is the smallest that covers it. Anything in the shaded band is within the Manual S limit.

Why this furnace calculator is different

Most furnace size calculators multiply your square footage by a number for your climate and stop there. The number varies from site to site, nobody says where it came from, and it runs high. This one does more.

  • It can measure your house. Your fuel bills record how much heat the house lost last winter. The tool turns that into a design load, the method state efficiency programs use to size replacement heating. None of the calculators we checked on Google's first page do it.
  • It checks the limit on oversizing. A furnace's output should be 100% to 140% of the design load. The tool shows where every standard size lands, so you can see when a quote is two sizes too big.
  • It keeps input and output apart. Furnaces are sold by input. Your house needs output. An 80,000 Btu/h furnace delivers 64,000 at 80% AFUE and 76,800 at 96%, and the tool does that conversion for every size.
  • It checks the furnace you already have. Many replacements are like for like. If the old one was oversized, that copies the mistake.
  • It uses real local climate data, not a five-region map: ASHRAE design temperatures and NOAA degree days, matched to the same airport weather station.

How it works (the math)

Square-footage method. The rule of thumb behind most furnace calculators, using the same table as our BTU calculator so the two tools agree:

Load (Btu/h) = sq ft x zone factor x (ceiling ft / 8) x insulation
zone factor  = 30, 35, 40, 45, 50, 55, 60 Btu/h per sq ft for zones 1 to 7
insulation   = 1.2 poor, 1.0 average, 0.9 good

Fuel-bill method. Last year's heating fuel, times the old furnace's efficiency, is the heat the house lost. Divide by the year's heating degree-hours and you have the house's heat loss per degree. Multiply by how far the design day falls below 65°F:

Heating fuel  = 12-month use - 12 x summer-month use
Heat delivered = heating fuel x Btu per unit x old AFUE
UA (Btu/h per F) = heat delivered / (HDD65 x 24)
Design load   = UA x (65 - 99% design temperature)

Btu per unit (EIA): therm 100,000 | CCF 103,600 | propane gal 91,452 | heating oil gal 138,500

The 65°F base matches the degree days. Efficiency Maine's Heat Load Estimator uses the same pairing, and GreenBuildingAdvisor's version of the method applies the equipment efficiency as this tool does. The summer subtraction, which takes out the water heater, stove and dryer, follows the Massachusetts Clean Energy Center's gas-bill worksheet.

Matching it to a furnace. Output = input x AFUE. A size fits when its output is 100% to 140% of the design load:

Input that fits = load / AFUE  to  1.4 x load / AFUE
Electric (Btu/h) = kW x 3,412   (x 0.75 on a 208 V supply)

The 140% ceiling is ACCA Manual S. ENERGY STAR writes it into its HVAC design rules as 100% to 140% of the design heat loss for a heating-only furnace, and allows more when the furnace blower also has to move air for central AC. Gas sizes are the 40,000 to 140,000 Btu/h input steps manufacturers sell. Electric sizes are heat kit ratings at 240 V from Goodman's spec sheet, with its 0.75 factor for 208 V.

Worked examples

A 2,000 square foot house in Chicago, by square footage

Chicago is zone 5, so the rule gives 2,000 x 50 = 100,000 Btu/h. At 96% AFUE the smallest furnace that covers it is a 120,000 Btu/h input, putting out 115% of the load. At 80% it takes a 140,000. That is what most calculators, and many quotes, would tell you.

The same house, by its gas bill

The owner burned 1,000 therms last year, about 20 a month in summer. Take out twelve summer months and 760 therms went to heat. Through an 80% furnace that is 60.8 million Btu delivered. O'Hare averages 5,974 heating degree days, so the house loses about 424 Btu/h per degree. Chicago's design temperature is 3.3°F, which is 61.7 degrees below 65, so the design load is 26,200 Btu/h.

The rule of thumb was 3.8 times that. Even a 40,000 Btu/h furnace, the smallest standard size, puts out 147% of this load, so the tool points to a two-stage or modulating model. The 100,000 Btu/h furnace in the basement is 305% of the load. It runs in short bursts all winter.

That gap is the normal result. A 2026 study by researchers at Purdue and Trane, funded in part by the Department of Energy and not yet peer reviewed, measured 74 houses in five climate zones. Their existing furnaces averaged 2.96 times the bill-method load, and a square-footage rule like this one gave the highest estimate of any method tested.

An electric furnace in Atlanta

A 1,500 square foot house in zone 3 comes to 60,000 Btu/h by the rule of thumb. At 240 V a 20 kW heat kit covers it (109% of the load). On a 208 V supply, common in apartments, the same kit makes only three quarters of its rated heat, so it takes a 25 kW kit (102%). If you are sizing electric heat this big, price a heat pump too.

What the estimate can't see

  • The bill method reads low if you heated with a wood stove or space heaters, kept the house cold, or left it empty for part of the winter. It reads high if the year was colder than normal. Use a typical year.
  • It needs one fuel doing the heating. It does not work for homes heated with electricity, because the summer baseline includes air conditioning.
  • Leaky ducts in an attic or crawlspace lose heat the bills already include, but a rule of thumb does not know about them.
  • Neither method is a Manual J. For a replacement, ask the contractor for the Manual J load and the quoted furnace's output, and check both against this.
  • Efficiency standards are changing. Federal rules require new non-weatherized gas furnaces to reach 95% AFUE from December 18, 2028. The rule is under legal challenge, so check its status before you buy an 80% unit.

Frequently asked questions

What size furnace do I need for a 2,000 square foot house?

By the usual rule of thumb, 60,000 Btu/h of output in a warm climate up to 120,000 in a very cold one. In Chicago that is 100,000 Btu/h, a 120,000 input furnace at 96% AFUE. Measured from fuel use, most houses need far less: the Chicago example above came to 26,200 Btu/h. Run your own bills through the tool before you accept a size.

How many BTU per square foot does a furnace need?

Rules of thumb use 30 Btu/h per square foot in the warmest US climates and 60 in the coldest. Worked out from fuel use, the Chicago house above needs 13.1. The tool shows the figure for your house in the "Per square foot" box.

What is the difference between furnace input and output BTU?

Input is the gas the furnace burns per hour, and it is the number in the model name. Output is the heat that reaches the ducts: input times efficiency. A 100,000 Btu/h furnace at 80% AFUE puts out 80,000. Size the output to the load, then pick the input that gets you there.

Is it bad to oversize a furnace?

Yes. An oversized furnace heats the house in short bursts and shuts off, so rooms swing in temperature, the blower is loud, and the igniter and controls wear faster. Carrier warns that excessive oversizing can make the furnace or its vent fail early. Manual S caps the output at 140% of the load.

Can I size a furnace from my gas bill?

Yes, and it is one of the better checks a homeowner can do. You need a year of use, a typical summer month to subtract the water heater and stove, the old furnace's efficiency, and your area's degree days and design temperature. The tool has the climate data built in for 71 cities.

Design temperatures and degree days by city

The climate data inside the tool, for reference. The design temperature is the ASHRAE 2021 99% heating dry-bulb: the outdoor temperature the airport stays above for 99% of the hours in the year. Degree days are NOAA's 1991 to 2020 normals at base 65°F, from the same station.

Show all 71 cities
City Zone 99% design HDD65
Anchorage, AK 7 -2.8°F 9,979
Fairbanks, AK 8 -37.6°F 13,420
Birmingham, AL 3A 24.9°F 2,533
Little Rock, AR 3A 24°F 3,165
Flagstaff, AZ 5B 9.9°F 6,746
Phoenix, AZ 2B 41.9°F 874
Fresno, CA 3B 34.8°F 2,187
Los Angeles, CA 3B 47°F 1,214
Sacramento, CA 3B 33.6°F 2,644
San Diego, CA 3B 47.2°F 990
San Francisco, CA 3C 42.2°F 2,475
Denver, CO 5B 5.8°F 5,862
Hartford, CT 5A 9.1°F 5,883
Washington, DC 4A 20.7°F 3,769
Wilmington, DE 4A 16.9°F 4,647
Jacksonville, FL 2A 32.8°F 1,228
Miami, FL 1A 52.7°F 104
Atlanta, GA 3A 26.4°F 2,531
Honolulu, HI 1A 65.1°F 0
Des Moines, IA 5A 0.4°F 6,178
Boise, ID 5B 16.4°F 5,321
Chicago, IL 5A 3.3°F 5,974
Indianapolis, IN 4A 7.5°F 5,250
Wichita, KS 4A 12.4°F 4,414
Louisville, KY 4A 15.7°F 3,936
New Orleans, LA 2A 36.6°F 1,176
Boston, MA 5A 12.8°F 5,545
Baltimore, MD 4A 17.5°F 4,484
Portland, ME 6A 5°F 6,795
Detroit, MI 5A 7.3°F 6,067
Grand Rapids, MI 5A 6.8°F 6,408
Duluth, MN 7 -12.1°F 9,115
Minneapolis, MN 6A -6°F 7,399
Kansas City, MO 4A 7.2°F 5,071
St. Louis, MO 4A 12.2°F 4,433
Jackson, MS 3A 26.8°F 2,222
Billings, MT 6B -2.7°F 6,754
Charlotte, NC 3A 24.8°F 3,058
Raleigh, NC 3A 23.6°F 3,153
Fargo, ND 6A -13.9°F 8,806
Omaha, NE 5A 1.6°F 5,833
Manchester, NH 5A 7°F 6,172
Newark, NJ 4A 16.2°F 4,701
Albuquerque, NM 4B 22.4°F 3,996
Las Vegas, NV 3B 35.4°F 1,836
Reno, NV 5B 19.5°F 4,669
Albany, NY 5A 4.3°F 6,357
Buffalo, NY 5A 6.8°F 6,466
New York City, NY 4A 17.3°F 4,553
Cleveland, OH 5A 9°F 5,516
Columbus, OH 4A 9.8°F 5,233
Oklahoma City, OK 3A 19°F 3,615
Portland, OR 4C 29.4°F 4,104
Philadelphia, PA 4A 17.8°F 4,510
Pittsburgh, PA 5A 9.2°F 5,572
Providence, RI 5A 12.8°F 5,478
Columbia, SC 3A 27°F 2,473
Sioux Falls, SD 6A -6.3°F 7,249
Nashville, TN 3A 19.5°F 3,364
Amarillo, TX 4B 16°F 3,872
Dallas, TX 2A 27.4°F 2,220
Houston, TX 2A 34.3°F 1,266
San Antonio, TX 2A 33.1°F 1,438
Salt Lake City, UT 5B 15.6°F 5,154
Richmond, VA 4A 21.2°F 3,736
Burlington, VT 6A -1.7°F 6,960
Seattle, WA 4C 30°F 4,376
Spokane, WA 5B 11.8°F 6,463
Milwaukee, WI 5A 2.8°F 6,450
Charleston, WV 4A 14.8°F 4,353
Cheyenne, WY 5B 3.1°F 6,959

Sources and methodology

Every figure on this page is pinned in fixtures.json and recomputed before each deploy; if the math and the words disagree, the build fails. All 71 cities' design temperatures and degree days were re-fetched from the sources and matched on November 4, 2026. Reviewed yearly. About Jake · Last reviewed November 4, 2026.

Cite this page

Free to cite or link in coursework, handouts, and articles — no permission needed.

Morrison, J. (2026, November 4). Furnace Size Calculator: Free BTU Sizing by Sq Ft or Gas Bill. DIYRated. https://diyrated.com/furnace-size-calculator/

Embed this tool on your site

Free for HVAC contractors, energy auditors, weatherization programs, home inspectors and home-improvement bloggers. Required attribution is in the snippet. No fee, no account, no tracking attached to the embed.

<iframe
  src="https://diyrated.com/furnace-size-calculator/embed/"
  width="100%"
  height="980"
  loading="lazy"
  style="border:1px solid #e5dcd0; border-radius:16px; max-width:900px;"
  title="Furnace Size Calculator: heating load and furnace BTU size (DIYRated)">
</iframe>
<p style="font-size:12px;color:#666;margin-top:8px">
  Furnace size calculator by
  <a href="https://diyrated.com/furnace-size-calculator/">DIYRated</a>
  &middot; Reviewed by Jake Morrison, Licensed GC
</p>